• Date: May 2017

This shows the corrosion that will start when two different types of metal are in contact with each other.  In this case the plumber did not use a dialectric connection between the brass and the copper.  This eventually will cause a leak if it is not corrected. At this home inspection this was found on the main water supply into the house. The solution is easy enough but due to its location, its going to take a bit of time.

Related Work

Heating fuel pipe at an inspected house in Kirkland

These are the small signs a home inspector will look for,

Pex Pipe Manifold at a Home inspection in Woodinville

Here you can see the pex piping comming into the distribu

retaining wall failure on inspected house in Seattle

This wall has failed it needs a good repair. Easy with th